Manufacturer GE Analog Module IC693ALG392

Description:

IC693ALG392 Analoga Current/Voltage Output Module pro PACSystems RX3i et Series 90-30.Modulus octo canales outputus simplicis finitae habet cum intentione outputs et/vel vena ansa outputs secundum institutionem ab utente.Singulis canalis generari potest conformatio programmatum ad scopes sequentes (0 ad +10 volts) ut unipolaris, (-10 ad +10 volts) bipolaris, 0 ad 20 milliamps, vel 4 ad 20 milliamps.Singuli canales interpretari possunt 15 ad 16 frusta.Hoc in limite fidens utentis praefertur.Omnes octo canales renovantur singulae octo millium secundorum.


Product Detail

Product Tags

depictio producti

IC693ALG392 Analoga Current/Voltage Output Module pro PACSystems RX3i et Series 90-30.Modulus octo canales outputus simplicis finitae habet cum intentione outputs et/vel vena ansa outputs secundum institutionem ab utente.Singulis canalis generari potest conformatio programmatum ad scopes sequentes (0 ad +10 volts) ut unipolaris, (-10 ad +10 volts) bipolaris, 0 ad 20 milliamps, vel 4 ad 20 milliamps.Singuli canales interpretari possunt 15 ad 16 frusta.Hoc in limite fidens utentis praefertur.Omnes octo canales renovantur singulae octo millium secundorum.

Modulus IC693ALG392 culpae filum apertum ad CPU refert pro utroque canali cum in modis currenti.Modulus ad ultimum notum statum pergere potest, cum ratio potentiae turbatur.Si potentia externa ad modulum continue applicatur, quilibet output suum ultimum valorem servabit vel ad zerum sicut figuratum retinebit.Installation in quavis I/O socors RX3i vel Series 90-30 ratio fieri potest.

Cuius moduli vim suam 24 VDC acquirere debet ab extrinseco fonte, qui directo modo clausus terminali iungitur.Singulae canales output singulae finitae sunt et officinas ad .625 µA accommodatas.Hoc potest mutare secundum intentionem.Usor notandum est, coram duris RF intervenientibus, moduli exactio ad +/-1% FS reduci potest pro currentibus outputibus et +/- 3% FS pro voltage outputs.Animadvertendum etiam est hunc modulum in clausura metallica ad rectam operationem figi debere.

Cubits technical

N. canales: 8
VoltageOutput dolor: 0 ad +10V (unipolaris) vel -10 ad +10V (bipolaris)
Current output dolor: 0 ad 20 mA seu 4 ad 20 mA
Renovatio Rate: 8 msec (all canales) ;
Max output Lond: 5 mA
Potentia consummatio: 110mA e +5 V bus vel 315 mA e + 24 V copia usoris

Technical Information

Numerus output canales I ad VIII selectable, una finita
Output Current dolor 4 ad 20 mA et 0 ad 20 mA
Output intentione dolor 0 ad X V et -10 V ad +10 V
Calibration Factory calibrated ad .625 µA pro 0 ad 20 mA;0.5 µA pro 4 ad 20 mA;et .3125 mV pro voltage (per comitem)
User Supple intentione (nominal) +24 VDC, e fonte voltage usuario suppleto
Externi Supple Voltage Range 20 VDC ad 30 VDC
Potentia Supple Rejectio Ratio (PSRR) CurrentVoltage 5 µA/V (typicum), 10 μA/V (maximum) ;25 mV/V (typicum), 50 mV/V (maximum) ;
Externae potestatis Supple Voltage Ripple 10% (maximum)
Internum Supple Voltage +5 VDC ex PLC backplane
Update Rate 8 milliseconds (approximas, omnes octo canales) Determinato tempore I/O scan, applicatione dependens.
Consilium:  

 

4 ad 20mA: 0.5 µA (1 LSB = 0.5 µA)
0 ad 20mA: 0.625 μA (1 LSB = 0.625 μA)
0 ad 10V: 0.3125 mV (1 LSB = 0.3125 mV)
-10 ad +10V: 0.3125 mV (1 LSB = 0.3125 mV)
Absoluta cura: 1  
Current Modus +/-0.1% plenae scalae @ 25°C (77°F), typica+/-0.25% plenae scalae @ 25°C (77°F), maximum+/-0.5% of scale in operating temperatus range (maximam)
Voltage Modus +/-0.25% plenae scalae @ 25°C (77°F), typica+/-0.5% plenae scalae @ 25°C (77°F), maximum+/-1.0% of scale in operating temperatus range (maximam)
Maximum Obsequium Voltage VUSER -3 V (minimum) ad VUSER (maximum)
User Lond (modus current) 0 ad 850 Ω (minimum ad VUSER = 20 V, maximum 1350 Ω ad VUSER = 30 V) (Load minus quam 800 Ω est temperatura dependens.)
Output Lond Capacitance (modus current) 2000 pF (maximum) ;
Output Lond Inductione (modus current) 1 H
Output Loading (voltage modus) output onus Capacitance 5 mA (2 K Ohms resistentia minima) (1 μF capacitas maximam)
Solitudo, Field ad Backplane (optical) et ad humum fabricare 250 VAC continuus;1500 VDC for 1 minute
Potentia consummatio  110 mA e +5 VDC PLC copia backplani
315 mA e +24 VDC usorum copia